Phone: (425)882-2206
FAX: (425)867-0865
E-mail: info@data-linc.com
DLM4100ET Extended Temperature Dial-up Modem

Appendix A

Specifications

Supply Voltage:

Power supply Specs:
   Input: 120VAC 60Hz
Output: 12VDC 800mA
   Power: 16 WATTS
Class 2 Transformer  UL 81J1 E81356  CSA LR99169
   Connection:  3.5x2.2 mm Barrel Connector

Current @ Maximum Operational Requirements: 260mA (Dialing, Speaker at full volume)

Wattage: 4W max

Operating Temperature Range: -40°F to +185°F (-40°C to +85°C)

Data Connections:
Phone Line Connection: RJ-11
RS-232 Connection: DB-9 Female
Physical Dimensions: 9" L x 4.9" W x 1.5" H (22.86 cm x 12.45 cm x 3.81 cm)

FCC Part 68 Data:
Reg. No. : DWEUSA-25983-M5-E
Ringer Equiv. : 1.0B Jack RJ-11

RS-232 Connector Pinout:

RS232 DLM4100ET DB-9 Pin Numbers
1 - Carrier Detect   6 - N/C
2 - Transmit Data 7 - N/C
3 - Receive Data 8 - N/C
4 - N/C 9 - N/C
5 - Signal Ground


DLM4100ET

Appendix B

Result Code Summary

    Number Statement Explanation
    0 OK Command Executed
    1 CONNECT Communications Established
    2 RING Ring Signal Detected
    3 NO CARRIER Carrier not detected, or Carrier lost
    4 ERROR Invalid Command line
    5 CONNECT 1200 Connect at 1200bps
    6 NO DIAL TONE Dial Tone not detected
    7 BUSY Busy detected
    8 NO ANSWER No silence detected
    10 CONNECT 2400 Connected at 2400bps
    11 CONNECT 4800 Connected at 4800bps
    12 CONNECT 9600 Connected at 9600bps

 

DLM4100ET

Appendix C

AT Command List

A = Answer Command
Bn = Select Communications Standard
n=0 Selects CCITT standards
n=1 Selects Bell standards
D = Dial Command
P = Pulse dial
T = Tone dial
W = Wait for dial tone
, = Pause for the duration of S8
@ = Wait for silence
! = Switch hook flash
; = Return to Command state
En = Command Echo
n=0 Do not echo commands
n=1 Enable command echo
Hn = Hook Control
n=0 Switch hook relay opens
n=1 Switch hook relay closes
Ln = Speaker Volume
n=0 Lowest speaker volume
n=1 Low speaker volume
n=2 Medium speaker volume
n=3 Loudest speaker volume
Mn = Speaker settings
n=0 Speaker off
n=1 Speaker on until carrier received
n=2 Speaker on
n=3 Speaker on after dialing until carrier is detected
Qn = Responses
n=0 Send responses
n=1 No responses
Sr? = Query Register
Sr = n  Set Register Value
Vn = Result Codes
n=0 Numeric result codes
n=1 Statement on screen - English
Xn = Result Code Set
n=0 Result codes 0 to 4
n=1 Result codes 0 to 5 and 10
n=2 Result codes 0 to 6 and 10
n=3 Result codes 0 to 5, 7, and 10
n=4 All result codes
Zn = Reset
n=0 Reset to profile 0
n=1 Reset to profile 1
&Gn = Guard Tone
n=0 Guard Tone disabled
n=1 Guard Tone disabled
n=3 1800Hz Guard Tone
&Pn = Dial Pulse Make/Break Ratio
n=0 39/61% @ 10pps
n=1 33/67% @ 10pps
&Tn = Test Modes
n=0 Exit Test Mode
n=1 Local Analog Loopback
n=3 Initiate local digital loopback
n=4 Respond to remote loop request
n=5 Deny remote loop request
n=6 Initiate a Remote Digital Loopback
n=7 Remote digital loopback with self-test
n=8 Local analog loopback with self-test
&Vn = View Configuration Profile
n=0 view profile 0
n=1 view profile 1

Return to Instructions: Dialing String


DLM4100ET

Appendix D

S-Registers

Register Range/Units Description Defaults
S0 0-255/Rings Number of rings before auto-answer 000
S1 0-255/Rings Count number of incoming rings 000
S2 0-127/ACSII Escape character 043
S3 0-127/ASCII Carriage return character 013
S4 0-127/ASCII Line Feed character 010
S5 0-32, ACSII   Backspace character 008
S6 2-255/sec Dial tone wait time 002
S7 1-255/sec Wait time for remote carrier 050
S8 1-255/sec Pause time for comma in command string 002
S9 1-255/0.1 sec Carrier detect response time 006
S10 1-255/0.1 sec Delay from loss of carrier to Hang-up 014
S11 50-255/msec DTMF dialing speed 095
S12 0-255/0.02 sec TIES Escape Code time limit 050
S30 Bit Mapped Sleep Mode timer 000

 

6/18/02
Content © 1996-2001 Data-Linc Group. All rights reserved. 020618DB